Asian Journal of atmospheric environment
Asian Journal of atmospheric environment Asian Journal of atmospheric environment
Asian Journal of atmospheric environment
  Aims and Scope Type of Manuscripts Best Practices Contact Information  
  Editor-in-Chief Associate Editors Editorial Advisory Board  

Journal Archive

Asian Journal of Atmospheric Environment - Vol. 15 , No. 4

[ Research Article ]
Asian Journal of Atmospheric Environment - Vol. 15, No. 4
Abbreviation: Asian J. Atmos. Environ
ISSN: 1976-6912 (Print) 2287-1160 (Online)
Print publication date 31 Dec 2021
Received 28 Jul 2021 Revised 30 Sep 2021 Accepted 08 Oct 2021
DOI: https://doi.org/10.5572/ajae.2021.089

Influence of Human Behavior on Indoor Air Quality in a Care Facility for the Elderly in Japan
Nobuyuki Tanaka* ; Tatsuji Munaka1)
Meteorology and Fluid Science Division, Central Research Institute of Electric Power Industry, 1646, Abiko, Abiko-shi, Chiba, 270-1194, Japan
1)Undergraduate School of Information and Telecommunication Engineering, Tokai University, Takanawa, 2-3-23, Minato, Tokyo, 108-8619, Japan

Correspondence to : * Tel: +81-7182-1181 E-mail: nobu@criepi.denken.or.jp


Copyright © 2021 by Asian Association for Atmospheric Environment
This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Funding Information ▼

Abstract

Volatile organic compounds (VOCs), CO2, temperature, and humidity in a private room in a care facility for the elderly were measured and the behavior of a resident and staff were recorded in order to clarify the effects of the resident’s behavior, especially defecation, on indoor air quality. Average indoor concentrations of total VOCs (in μg m-3) in summer, autumn, and winter were 40.9, 16.7, and 18.8, respectively. Average indoor concentrations of CO2 in summer, autumn, and winter were 813, 761, and 1144 ppm, respectively, revealing a tendency for the concentrations of CO2 to be higher in winter, in contrast to the VOC concentration. The concentrations of VOCs and CO2 were 1.1 to 1.5 times higher when the resident was present in the room than when the resident was absent. This result suggests that one of the main sources of VOC and CO2 emissions in indoor air was the resident. Acetic acid, 1-butanol, propanoic acid, hexanoic acid, and phenol, which are contained in human sweat, exhaled air, and excrement, were the predominant VOCs in the air of the room regardless of the season, and these five components accounted for more than 90% of the total VOCs. The concentrations of these components were higher when the resident was present in the room, suggesting that the resident was the main source of these components. Based on the changes in the VOC and CO2 concentrations over time and the records of the resident and the staff, it was noted that VOC concentrations decreased, in some cases, before and after diaper changes. Our research suggests that certain aspects of the behavior of residents can be inferred by monitoring changes in indoor air quality.


Keywords: Elderly care facility, Indoor air, Volatile organic compounds, Human behavior, Diaper change

1. INTRODUCTION

The number of elderly people in Japan continues to increase. As of June 2021, there are 36.34 million elderly people aged 65 or over in Japan, accounting for 29% of the total population (SBJ, 2021). This number is expected to reach 39.21 million in 2040, accounting for 35.3% of the total population (IPSS, 2017). As the number of elderly people increases, so does the number who need assistance and care. Those aged 65 or over who were certified as needing care rose from 4.91 million in 2010 to 6.45 million in 2018 (Cabinet Office Japan, 2021). As a result, the number of elderly people moving into nursing homes and using home care services has been increasing year by year, and this trend is expected to continue (MHLW, 2021).

In Japan, nursing homes and other facilities for the elderly are required by law to have at least one caregiver for every three residents (MHLW, 1999). Caregivers provide a wide range of services to residents, and many caregivers complain of physical disability, especially back pain (Shogenji et al., 2006; Onuki et al., 2004). In addition to bathing (Kawahara et al., 2010), diaper changing is a common cause of back pain among caregivers (Shogenji et al., 2006; Onuki et al., 2004; Japan Institute of Personnel Administration, 2000).

More than 50% of residents of care facilities for the elderly in Japan use diapers (Ogata et al., 1997), and caregivers spend about 20% of their work time on toileting care, which includes changing diapers (Kooka et al., 2013). In many cases, toileting care is provided in response to requests from elderly residents, but in some cases, there has not been any excretion or defecation, in which case caregivers lose work time. This loss of time may translate into there being insufficient time for the caregiver to perform care that is actually needed by the residents. In other words, if caregivers can anticipate when elderly residents need care, they will be able to provide higher quality services to them at the appropriate time. One potential way to achieve this is to use sensors and other devices to better understand the behavior of elderly people and identify services that are appropriate for their situation. Many studies have already been conducted on the use of sensors to watch over elderly people. For example, Nakano et al. (2016, 2015) developed a method to predict the behavior of elderly people by monitoring the electricity usage in their homes. Takama et al. (2017) analyzed logs acquired from various sensors installed in care facilities for the elderly and from sensors worn by care staff, and they reported that the work of care staff and the residents’ sleep status could be estimated. In addition to the above, other examples of using force sensors (Hatsukari et al., 2012; Matsuoka et al., 2012) and camera images (Oda and Fujiwara, 2010) to estimate the behavior of the elderly have been reported.

There are thus many reports on understanding the behavior of elderly people based on the physical indicators of both the indoor facilities and the people living and working in them. On the other hand, only a few reports have sought to better understand the behavior of elderly people based on changes in the concentrations of chemical components in the indoor environment (e. g., Oyabu et al., 2001; Sawada et al., 2001; Suzuki et al., 2001). However, since chemical substances are emitted through human activities such as excretion, it is possible to estimate human activities by understanding the changes in their concentrations.

Volatile organic compounds (VOCs), which account for most of the components emitted as a result of human activities such as excretion, are diverse (Li et al., 2020) and their amounts and compositions can vary greatly depending on the type of activity and the environment (Vardoulakis et al., 2020; Nazaroff, 2013; Milner et al., 2011). In addition, sensors that can monitor VOCs in real time are commercially available, but such sensors typically display only the total VOC (TVOC) concentration and cannot measure individual VOCs. The purpose of this study was to clarify the relationships between human behavior and indoor air quality by measuring indoor air quality, especially VOCs, as well as to gain a better understanding of the behavior of elderly residents and staff in a care facility setting. This study examines relationships between changes in VOC concentrations as a result of defecation and the timing of diaper changes, which are a significant work burden for caregivers in care facilities for the elderly.


2. EXPERIMENTAL
2. 1 Monitoring Site

The indoor air was monitored in a private room of a three-story reinforced concrete facility for the elderly located in the Kanto region of Japan. An outline of the private room is shown in Fig. 1. The room has an area of about 18 m2 and a volume of about 43.2 m3, and is equipped with an air conditioner as well as a sash window and a natural ventilation port. In both the private room and the building, heating and cooling are provided by electricity, and no combustion heating is used. The resident, a male in his 80s, is unable to walk on his own and always uses a wheelchair for mobility. He needs assistance to stand up and sit down. He continually wears diapers and does not use the toilet in his private room. He eats all three meals in the communal dining room and takes a bath once every three days. Except for having meals and bathing, he spends most of his time lying in bed. In collecting personal information, informed consent were given to the resident and the care facility in advance, and their consent was obtained. In addition, this study was conducted in accordance with the “Ethical Guidelines for Research Involving Human Subjects” set forth by the Central Research Institute of Electric Power Industry, to which the corresponding author belongs.


Fig. 1. 
Outline of the private room in the care facility. The room has an area of about 18 m2, a ceiling height of 2.4 m, and a volume of 43.2 m3.

2. 2 Sample and Data Collection

Sample and data collection was conducted on three consecutive days in summer ( July 29-31, 2020), autumn (November 9-11, 2020), and winter (February 8-10, 2021). A temperature, humidity and a CO2 sensor (2JCIE-BU01, OMRON) were placed on a shelf at a height of about 1 m, and data were acquired every 10 s (Fig. 1). In addition, adsorbent tubes filled with Tenax TA® (3.5 in.×0.25 in. outer diameter, 60/80 mesh, COMSCO), which were previously conditioned at 300°C for 1 h, were mounted on a tube sampler (MTS-32, Markes International). The tube sampler was placed on a shelf about 1 m high, and the room air was aspirated at 0.1 L min-1 for 1 h for collection of each sample (Fig. 1). The sampler was used to collect samples continuously for about 48 h from around noon on the first day to around noon on the third day during each sampling campaign. The adsorbent tubes were tightly sealed and stored in a cool, dark place after sample collection. An infrared camera was installed on the wall (Fig. 1) at a height of about 1.8 m to capture images of the room every 10 s in order to monitor the behavior of the resident and staff, the opening and closing of the sash window, and the use of the air conditioner.

2. 3 Analytical Procedure

VOCs were quantified by gas chromatography-mass spectrometry system (GC/MS; GCMS-QP2020, Shimadzu Corporation) equipped with a thermal desorption injector (TD-GC/MS; TDTS-2020, Shimadzu Corporation). The target VOCs for analysis were eight volatile fatty acids (VFAs: acetic acid, propanoic acid, isobutyric acid, butyric acid, isovaleric acid, valeric acid, hexanoic acid, and heptanoic acid), three alcohols (2-butanol, 1-propanol, and 1-butanol), three phenols (phenol, 4-methylphenol, and 4-ethylphenol), one sulfur compound (dimethyl disulfide), two indoles (indole and skatole), and three ketones (2-butanone, 2-pentanone, and 3-pentanone). An InertCap WAX capillary column (30 m×0.25 mm×0.25 μm, GL Sciences) was used for separation. Compounds collected on the adsorbent were desorbed for 3 min at 230°C with a purge flow of 50 mL min-1 with trapping at -20°C. The cold trap was rapidly heated to 230°C and the trapped chemical substances were injected into the GC/MS. The GC oven temperature program was as follows: 40°C (hold 3 min) → (ramp 8°C min-1) → 230°C (hold 5 min). The temperature of the injection port and the ion source was 200°C and 210°C, respectively. The samples were analyzed using the selected ion monitoring mode. For signal quantification, standard solutions of the analytes at 1, 10, and 100 ng μL-1 were measured by TD-GC/MS.


3. RESULTS AND DISCUSSION
3. 1 Overview of Indoor Air Quality

An overview of the measurement results for each sampling period is given in Table 1. The average concentration (μg m-3) of the sum of the 18 VOCs targeted in this study (TVOC) in the private room for each period was 40.9 in summer, 16.7 in autumn, and 18.8 in winter, thus indicating that the TVOC concentration was highest in summer. However, the average concentration for indoor CO2 (ppm) was 813 in summer, 761 in autumn, and 1,144 in winter, showing a tendency for higher CO2 concentrations in the winter, in contrast to the TVOC concentration. The average indoor temperature was 25.3°C in summer, 23.4°C in autumn, and 22.8°C in winter, with little difference between the seasons owing to the use of air conditioning and heating in the room. The average relative humidity in the room was 68.3% in summer, 36.9% in autumn, and 26.3% in winter; thus, the humidity was highest in the summer and lowest in the winter. The relatively higher concentrations of TVOCs in summer compared with the other seasons may be due to the high emissions of VOCs caused by perspiration from the resident and staff. Although the room in the facility was air-conditioned and the average indoor temperature was maintained at 25.3°C even during summer, this was hotter than in the other seasons, which may have encouraged perspiration. However, the high relative humidity during summer may have contributed to the increase in the VOC concentrations. Markowicz and Larsson (2015) reported that an increase in relative humidity indoors promotes desorption of VOCs from surfaces. The high VOC concentrations during summer in this study may have been partly due to the high relative humidity. In addition, the relatively high concentrations of CO2 in the winter were attributed to decreased ventilation efficiency, since neither the private room nor the facility used combustion heating. Further, the reason why the average concentration of CO2 was relatively lower in the autumn may be because, unlike the other seasons, there were times when the windows of the private rooms were open during the observation period. This is consistent with the fact that the CO2 concentration was low, at around 500-600 ppm, even though the resident was present during the time when the windows were open.

Table 1. 
Overview of the indoor air quality during each sampling campaign.
All data Resident present Resident absent P/A2)
Average SD1) Average (P) SD1) Average (A) SD1)
Summer TVOC3) [μg m-3] 40.9 10.7 43.9 10.0 37.1 10.3 1.18
CO2 [ppm] 813 116 825 91 731 95 1.13
Temperature [°C] 25.3 0.4 25.3 0.4 25.4 0.5 0.99
RH4) [%] 68.3 4.0 67.9 3.2 69.9 5.7 0.97
Autumn TVOC3) [μg m-3] 16.7 8.2 17.1 7.4 11.3 6.2 1.51
CO2 [ppm] 761 137 780 143 675 54 1.16
Temperature [°C] 23.4 1.3 23.3 1.1 23.6 1.6 0.99
RH4) [%] 36.9 8.6 36.2 9.0 39.2 7.9 0.93
Winter TVOC3) [μg m-3] 18.8 9.1 20.3 9.1 15.9 9.2 1.28
CO2 [ppm] 1144 172 1180 161 1005 113 1.17
Temperature [°C] 22.8 1.6 23.0 1.6 22.4 1.5 1.03
RH4) [%] 26.3 2.7 26.7 2.6 25.2 2.4 1.06
1)Standard deviation. 2)Ratio of the concentration when the resident was present (P) to that when the resident was absent (A). 3)Total volatile organic compounds. 4)Relative humidity.

A summary of the effects of the residents’ presence or absence on indoor air quality is given in Table 1. This table shows that the TVOC and CO2 concentrations were higher when the resident was present in the room in all seasons, with values ranging from 1.1 to 1.5 times higher than those when the resident was absent. This result indicates that the presence of the resident in the room is one of the main sources of emission of VOCs and CO2 in the indoor air. Mitova et al. (2020) evaluated the effect of the presence and absence of people on indoor concentrations of chemicals and found that the concentrations of VOCs such as isoprene and formaldehyde increased when people were in the room. Our results were similar to those of Mitova et al., although the components targeted in the present study were different. However, the temperature and relative humidity remained nearly constant regardless of the presence or absence of the resident. This is thought to be because the facility’s air conditioning unit was always in operation, thus maintaining a relatively constant temperature and humidity.

3. 2 Composition of Indoor VOCs

The average concentration and standard deviation for each VOC in the room are given in Table 2. For all seasons, among the 18 VOCs targeted, acetic acid had the highest concentrations, accounting for more than 50% of the TVOCs. Acetic acid and five other VOCs, namely, 1-butanol, propanoic acid, hexanoic acid, and phenol, were predominant regardless of the season, accounting for more than 90% of the TVOCs. Table 2 also shows the average concentration ratio for each component when the resident was present and absent. From the table, it is clear that the concentrations of most VOCs were higher when the occupant was in the room. Short chain fatty acids (SCFAs) such as acetic acid are produced as a result of fermentation of indigestible foods by gut microbiota (e.g., Lee and Zhu, 2021; Baxter et al., 2019; Raninen et al., 2016). The formation of SCFAs is influenced by various factors such as the pattern of food intake, antibiotic treatment, and microbial populations (Lee and Zhu, 2021). Phenols are produced by intestinal microorganisms from tyrosine, one of the main amino acids (Smith and MacFarlane, 1996), and their production is correlated with dietary protein intake (Geypens et al., 1997). These components are found in exhaled air as well as in sweat (Casas-Ferreira et al., 2019; Meijerink et al., 2000) and excreta (Casas-Ferreira et al., 2019). Therefore, one of the main sources of these VOCs in the indoor air is considered to be the resident. This is consistent with the fact that the VOC concentrations were higher when the resident was present in the room than when he was absent.

Table 2. 
Concentrations of indoor VOCs for each sampling campaign.
Summer (n=43) Autumn (n=48) Winter (n=48)
Concentration [μg m-3] SD1) P/A2) Concentration [μg m-3] SD1) P/A2) Concentration [μg m-3] SD1) P/A2)
2-Pentanone ND4) *5) *5) 0.0265 0.184 ND3) ND4) *5) *5)
2-Butanol 0.572 0.101 0.924 ND4) *5) *5) 0.0143 0.0992 ND3)
1-Propanol 1.06 1.69 1.53 0.0126 0.0870 ND3) ND4) *5) *5)
Dimethyl disulfide 0.112 0.267 7.51 0.0270 0.118 1.06 0.664 1.18 1.34
1-Butanol 6.31 2.79 1.23 2.33 1.67 1.06 1.68 0.795 1.13
Acetic acid 24.7 8.39 1.13 9.19 4.42 1.54 12.8 7.75 1.28
Propanoic acid 1.87 0.700 1.39 1.00 0.955 3.05 1.14 0.748 1.35
Isobutyric acid 0.935 0.169 1.15 0.799 0.661 1.62 0.699 0.367 0.900
Butanoic acid 0.896 0.237 1.33 0.632 0.481 1.48 0.179 0.240 ND3)
Isovaleric acid 0.207 0.0815 1.16 0.221 0.333 1.50 0.0221 0.0733 0.459
Pentanoic acid 0.493 0.192 1.30 0.411 0.357 1.80 0.109 0.316 0.739
Hexanoic acid 1.64 0.622 1.41 0.861 0.514 1.76 0.315 0.196 1.60
Heptanoic acid 0.133 0.298 ND3) 0.111 0.198 5.23 ND4) *5) *5)
Phenol 1.67 0.358 1.02 0.949 0.597 1.28 1.01 0.390 1.25
p-Cresol 0.214 0.0416 1.14 0.101 0.194 1.43 0.0766 0.0325 1.50
p-Ethylphenol 0.0525 0.0152 0.764 0.0216 0.127 ND3) 0.00214 0.0148 ND3)
Indole 0.0294 0.0122 1.26 0.0113 0.0736 ND3) 0.0105 0.0391 ND3)
Skatole ND4) *5) *5) 0.00657 0.0455 ND3) ND4) *5) *5)
Total 40.9 10.7 1.18 16.7 8.24 1.51 18.8 9.15 1.26
1)Standard deviation. 2)Ratio of the concentration when the resident was present (P) to that when the resident was absent (A). 3)Detected when the resident was present but not when the resident was absent. 4)Not detected regardless of the presence or absence of the resident. 5)No data.

The correlations among the components of indoor VOC concentrations in each season are shown in Fig. 2, indicating that the correlations among VFAs and phenols tend to be relatively high regardless of the season. However, the correlations between components not of the same type were not very high, especially for alcohols and ketones. The high correlation between VFAs and phenols may be attributable to the fact that they are produced as a result of a series of fermentation reactions and microbial metabolism in the body. In contrast, alcohols and ketones have production mechanisms in the body that are different from those of the other components, and thus their correlations with the other components were low.


Fig. 2. 
Correlation coefficients (r) among the VOCs during each sampling campaign. 1, 2-pentanone; 2, 2-butanol; 3, 1-propanol; 4, dimethyl disulfide; 5, 1-butanol; 6, acetic acid; 7, propanoic acid; 8, isobutyric acid; 9, butanoic acid; 10, isovaleric acid; 11, pentanoic acid; 12, hexanoic acid; 13, heptanoic acid; 14, phenol; 15, p-cresol; 16, p-ethylphenol; 17, indole; 18, skatole; 19, total.

3. 3 Relationship between Human Activities and Indoor Air Quality

The temporal changes of indoor VOC and CO2 concentrations and the behavior of the resident and staff in each season are shown in Fig. 3. In the figure, the timing of the entry by staff into the room is indicated by a small dot given that staff were typically in the room for only 5 min at most. The windows in the room were always closed except in autumn, and the air conditioner was not used except in summer. In addition, for diaper changes, although toileting care was noted in the facility’s records, urinary excretion (and not defecation) was noted in all instances and the quantity was unknown.


Fig. 3. 
Temporal changes of indoor VOC and CO2 concentrations and the behavior of the resident and staff for each season. Some data on the CO2 concentration in autumn could not be obtained owing to a failure of the sensor. A red dotted line indicates that the VOC concentrations decreased before and after a diaper change.

As shown in Fig. 3, the VOC concentrations in the air of the room tended to increase or decrease within a relatively short period of time. Also, as shown in Table 2, the VOC concentrations tended to be higher when the resident was in the room for all seasons, and the VOC concentrations increased and decreased significantly even when the resident was in the room. This result suggests that the behavior of the resident may have some influence on the indoor VOC concentration. However, no relationship was observed between the timings of staff entry and the VOC concentrations. This may be because, with the exception of a few cases, the staff members were in the room for only about 5 min, a time which did not affect the VOC concentrations given the low temporal resolution of the measurement technology. In contrast, when staff entered the room the CO2 concentration increased and then decreased after they left, in some cases, suggesting that the staff’ behavior could be captured owing to the high temporal resolution of the CO2 sensor.

The resident in question is paralyzed, wears diapers at all times, and spends most of his time indoors lying in bed. His autonomous physical activity is limited to small movements of the arms and legs. Therefore, the emission sources of VOCs originating from the resident are considered to be limited to exhalation, body odor, and excretion. Of these, VOCs due to exhalation and body odor are considered to be emitted at approximately the same rate when the resident is in the room. However, VOCs derived from defecation are considered to be emitted during the period between defecation and a diaper change. Fig. 3 shows that, for most cases, VOC concentrations increased before a diaper change and decreased after a diaper change in summer. However, in autumn and winter, VOC concentrations decreased before and after diaper changes in fewer cases than in summer and were more pronounced in winter. These results suggest that defecation and diaper changing may be one of the causes of the increase or decrease in indoor VOC concentrations. For the scenario where the VOC concentrations decreased after changing the diaper, the concentration ratio of each VOC before and after the change (VOC concentration after the change to VOC concentration before the change) is shown in Fig. 4. The decrease in the VOC concentration was more pronounced for VFAs, as represented by acetic acid. Given that VFAs such as acetic acid are frequently detected in feces, it is reasonable that the concentrations of the VFAs decreased after a diaper change.


Fig. 4. 
Ratio of VOC concentrations after a diaper change to that before diaper change in the case where VOC concentrations decrease after diaper change. x, not detected both before and after a diaper change; y, detected before diaper change but not after; z, detected after a diaper change but not before.

There were, however, some cases where the indoor VOC concentrations did not change or increased after a diaper change. The reason for this is not clear, but it is possible that if the amounts of excretion and/or defecation were very small, very few VOCs would have been emitted. The resident had his diaper changed every few hours, and it is thought that there were some cases in which the amount of excretion and defecation was extremely small or there was no excretion and defecation. In addition, the resident used relatively thick bedding in the winter, which may have suppressed the volatilization of VOCs from the bedding. In fact, there were few cases where the VOC concentrations increased before diaper change in the winter. In addition, the measurement frequency of VOCs in this study was one sample per hour, and the temporal resolution was not high. Therefore, it is possible that a temporary increase in concentration was not captured. Furthermore, the ventilation rate is not expected to be constant at all times, which would also affect the indoor VOC concentrations.

The hourly changes in the composition of the VOCs for each season are shown in Fig. 5. Although the concentrations of acetic acid and 1-butanol, the major constituents, remained relatively constant throughout all seasons, the composition of the constituent VOCs did change within short periods of time. For example, in summer, the proportion of 1-propanol increased after 19:40 on July 30. Although the reason for this increase is not clear, it may be because the resident had eaten fruit that contained a lot of 1-propanol at dinner that evening shortly before the measurement. In addition, the ratio of VFAs other than acetic acid and phenol temporarily increased in the sample at 12:40 on November 10 (autumn). At this time, two research workers were working in the room for about an hour for sampling. The temporary change in composition may have been influenced by the VOCs originating from the researchers. Overall, the results suggest that detailed information on human behavior, diet, and other aspects can be extracted by analyzing changes in the indoor concentrations and composition of VOCs.


Fig. 5. 
Hourly changes in the composition of VOCs for each season.


4. CONCLUSION

To clarify the relationships between a resident’s behavior and indoor air quality in a care facility for the elderly, VOC and CO2 concentrations, temperature, and humidity were measured and the resident’s behavior was ascertained from camera images installed in the room. The TVOC concentrations in the indoor air had a tendency to be higher in summer, whereas the CO2 concentrations were higher in the winter. Given that the concentrations of both VOCs and CO2 were higher when the resident was present, it was considered that the resident was one of the main sources for these components. Among the 18 VOCs targeted, acetic acid, 1-butanol, propanoic acid, hexanoic acid, and phenol, which are contained in human sweat and excrement, were the most prevalent VOCs, regardless of season, and their concentrations were relatively high when the occupant was present in the room. These findings suggest that these VOCs may have been emitted from the sweat and feces of the occupant. Finally, as a result of evaluating the relationships between the behavior of the resident and staff and the VOC concentrations, the VOC concentrations were found to increase before diaper changes and to decrease after the changes in many cases. This indicates that the timing of defecation can be estimated by monitoring the resulting VOC concentrations.


Acknowledgments

The authors heartily thank Mr. S. Fukumori and Mr. Y. Nakashima (Electric Power Engineering Systems Co., Ltd., Japan) for assistance in sample collection and sample analysis. This work was supported by JSPS KAKENHI Grant Number JP19K12208.

CONFLICTS OF INTEREST

The authors declare no conflicts of interest.


References
1. Baxter, N.T., Schmidt, A.W., Venkataraman, A., Kim, K.S., Waldron, C., Schmidt, T.M. (2019) Dynamics of human gut microbiota and short-chain fatty acids in response to dietary interventions with three fermentable fibers. mBio, 10, e02 566-18.
2. Cabinet Office Japan (2021) Annual Report on the Ageing Society, 31 pp (in Japanese).
3. Casas-Ferreira, A., Nogal-Sánchez, M., Pérez-Pavón, J.J., Moreno-Cordero, B. (2019) Non-separative mass spectrometry methods for non-invasive medical diagnostics based on volatile organic compounds: A review. Analytica Chimica Acta, 1045, 10-22.
4. Geypens, B., Claus, D., Evenepoel, P., Hiele, M., Maes, B., Peeters, M., Rutgeerts, P., Ghoos, Y. (1997) Influence of dietary protein supplements on the formation of bacterial metabolites in the colon. Gut, 41(1), 70-76.
5. Hatsukari, T., Shiino, T., Murai, S. (2012) The reduction of tumbling and falling accidents based on a built-in patient alert system in the hospital bed. Journal of Science of Labour, 88(3), 94-102, (in Japanese).
6. IPSS (National Institute of Population and Social Security Research) (2017) Population Projections for Japan: 2016-2065, Population Research Series No. 336 July 31, 2017 (in Japanese).
7. Japan Institute of Personnel Administration (2000) Comprehensive research and study on working conditions for caregivers and other welfare-related personnel (in Japanese).
8. Kawahara, Y., Miwa, C., Deguchi, A., Mizutani, Y. (2010) Current state of bathing care and necessity of new equipment for bathing care in nursing care institution. Journal of Human and Living Environment, 17, 23-30, (in Japanese).
9. Kooka, A., Suyama, K., Katagai, S., Tanaka, K. (2013) Effects on care workers of an educational program aimed at collaboration in excretion care at elderly care facilities. Japanese Journal of Gerontology, 34(4), 491-499, (in Japanese).
10. Lee, J.H.J., Zhu, J. (2021) Analyses of short-chain fatty acids and exhaled breath volatiles in dietary intervention trials for metabolic diseases. Experimental Biology and Medicine, 246, 778-789.
11. Li, K., Shen, J., Zhang, X., Chen, L., White, S., Yan, M., Han, L., Yang, W., Wang, X., Azzi, M. (2020) Variations and characteristics of particulate matter, black carbon and volatile organic compounds in primary school classrooms. Journal of Cleaner Production, 252, 119804.
12. Markowicz, P., Larsson, L. (2015) Influence of relative humidity on VOC concentrations in indoor air. Environmental Science and Pollution Research, 22, 5772-5779.
13. Matsuoka, S., Ogawa, H., Maki, H., Yonezawa, Y. (2012) A wearable care support system for wandering elderly persons. Life Support, 24(2), 79-85 (in Japanese).
14. Meijerink, J., Braks, M.A.H., Brack, A.A., Adam, W., Dekker, T., Posthumus, M.A., Van Beek, T.A., Van Loon, J.J.A. (2000) Identification of olfactory stimulants for Anopheles gambiae from human sweat samples. Journal of Chemical Ecology, 26(6), 1367-1382.
15. MHLW (Ministry of Health, Labour and Welfare Japan) (1999) MHLW Order No. 39, Article 2 (in Japanese).
16. MHLW (Ministry of Health, Labour and Welfare Japan) (2021) Survey of social welfare facilities, https://www.mhlw.go.jp/toukei/list/23-22c.html, 2021/6/25 access (in Japanese).
17. Milner, J., Vardoulakis, S., Chalabi, Z., Wilkinson, P. (2011) Modelling inhalation exposure to combustion-related air pollutants in residential buildings: Application to health impact assessment. Environment International, 37, 268-279.
18. Mitova, M.I., Cluse, C., Goujon-Ginglinger, C.G., Kleinhans, S., Rotach, M., Tharin, M. (2020) Human chemical signature: Investigation on the influence of human presence and selected activities on concentrations of airborne constituents. Environmental Pollution, 257, 113518.
19. Nakano, Y., Ueno, T. (2015) Watching system for aged single person based on electricity use part 1: method inferring residents’ direct operation of electric appliances from total load current of household. IEEJ Transactions on Electronics, Information and Systems, 135(5), 471-480, (in Japanese).
20. Nakano, Y., Ueno, T. (2016) Watching system for aged single person based on electricity use part 2: method using average of total load current of household. IEEJ Transactions on Electronics, Information and Systems, 136(6), 767-774, (in Japanese).
21. Nazaroff, W. (2013) Exploring the consequences of climate change for indoor air quality. Environmental Research Letters, 8, 015022.
22. Oda, A., Fujiwara, Y. (2010) Watching sistem for care facilities of the elderly. Journal of the Robotics Society of Japan, 28(9), 1075-1076, (in Japanese).
23. Ogata, M., Yamada, H., Tose, M. (1997) Measurement of the physical work capacity of caregivers in a geriatric health facility and a plan for improving work performance. Kawasaki Journal of Medical Welfare, 7(1), 33-45 (in Japanese).
24. Onuki, Y., Takeda, H., Oeda, Y., Kitagawa, J., Maruyama, T., Nakahara, Y. (2004) Physiological demands during changing adult diapers of nursing staffs at a health welfare facility. Japan Society of Physiological Anthropology, 9(3), 109-114. (in Japanese).
25. Oyabu, T., Sawada, A., Nanto, H. (2001) Identification of basic indoor human behaviors using odor-sensor array. TIEE Japan, 121-E, 20-25 (in Japanese).
26. Raninen, K.J., Lappi, J.E., Mukkala, M.L., Tuomainen, T-P., Mykkänen, H.M., Poutanen, K.S., Raatikainen, O.J. (2016) Fiber content of diet affects exhaled breath volatiles in fasting and postprandial state in a pilot crossover study. Nutrition Research, 36, 612-619.
27. Sawada, A., Oyabu, T., Nanto, H. (2001) Recognition of human behaviors by Mahalanobis’ generalized distance in odor-sensor characteristics. Life Support, 13(2), 2-7 (in Japanese).
28. SBJ (Statistics Bureau of Japan) (2021) Population Census. https://www.stat.go.jp/data/jinsui/new.html, 2021/6/25 access (in Japanese).
29. Shogenji, M., Iumi, K., Hiramatsu, T. (2006) Clarification of range of lumbosacra1 angle and lumbosacral load in changing diapers at disabled elderly by the caring staffs. Journal of Japan Academy of Gerontological Nursing, 11(1), 39-46 (in Japanese).
30. Smith, E.A., Macfarlane, G.T. (1996) Enumeration of human colonic bacteria producing phenolic and indolic compounds: effects of pH, carbohydrate availability and retention time on dissimilatory aromatic amino acid metabolism. Journal of Applied Bacteriology, 81(3), 288-302.
31. Suzuki, R., Otake, S., Izutsu, T., Iwatani, T. (2001) Time-course analysis of activities of daily living in aged person living alone. Life Support, 13(4), 18-25 (in Japanese).
32. Takama, Y., Fujimoto, Y., Yamaguchi, T., Nitta, O., Yorisaki, E., Koujima, K. (2017) Activity analysis of caretakers and residents of nursing-care homes based on sensor log. Intelligence and Information, 29(4), 619-627 (in Japanese).
33. Vardoulakis, S., Giagloglou, E., Steinle, S., Davis, A., Sleeuwenhoek, A., Galea, K.S., Dixon, K., Crawford, J.O. (2020) Indoor exposure to selected air pollutants in the home environment: A systematic review. International Journal of Environmental Research and Public Health, 17(23), 8972.